Published November 2011 | Version v1
Journal article

Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign

  • 1. Slovak Medical University in Bratislava, Limbová 12, 833 03 Bratislava (Slovakia)
  • 2. Nofer Institute of Occupational Medicine, St. Teresa Str 8, 91 348 Lodz (Poland)
  • 3. Greek Atomic Energy Commission (GAEC), Ag. Paraskevi, 15310 Athens (Greece)
  • 4. Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses (France)
  • 5. Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, B-2400 Mol (Belgium)
  • 6. University Hospital Centre (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne (Switzerland)

Description

The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10–12% increase in the number of IR examinations every year (). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed. The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses. -- Highlights: ► We present a set of data on extremity doses for staff in selected interventional radiology procedures. ► We studied the influence of different parameters. ► The measured doses are analyzed according to the operators skill,his position during work, tube configuration, etc. ► Maximum doses recorded for all types of embolisation, in all locations of dosemeters on the staff body. ► The results were compared with established dose limits and extremity doses published by another authors.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2011.07.038

Additional details

Identifiers

DOI
10.1016/j.radmeas.2011.07.038;
PII
S1350-4487(11)00383-0;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
46
Journal Issue
11
Journal Page Range
p. 1210-1215
ISSN
1350-4487
CODEN
RMEAEP

Conference

Title
International workshop on optimization of radiation protection of medical staff
Acronym
ORAMED 2011
Dates
20-22 Jan 2011
Place
Barcelona (Spain)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44087401
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; DOSE LIMITS; DOSEMETERS; EYES; HANDS; OCCUPATIONAL EXPOSURE; PATIENTS; PERSONNEL DOSIMETRY; PERSONNEL MONITORING; RADIATION DOSES; SURGERY
Descriptors DEC
ARMS; BODY; DIAGNOSTIC TECHNIQUES; DOSES; DOSIMETRY; FACE; HEAD; LIMBS; MEASURING INSTRUMENTS; MEDICINE; MONITORING; NUCLEAR MEDICINE; ORGANS; RADIATION MONITORING; RADIOLOGY; SAFETY STANDARDS; SENSE ORGANS; STANDARDS

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.