Published February 1981 | Version v1
Report

Similarities in the lethal and mutagenic effects of sunlight and artificial light in mammalian cells

  • 1. Bureau of Radiological Health, Rockville, MD

Description

A mouse lymphoma cell assay system was used to determine relative mutagenicity and lethality of the radiation emitted by sunlight and several commonly encountered fluorescent-type artificial light sources. Comparison of the times required to either double the spontaneous mutation frequency or decrease cell survival by 50 percent showed that for 4 lamps, fluorescent radiation was 0.5 to 5 percent as mutagenic, and sunlamp radiation was 8 times as mutagenic, as sunlight. The fluorescent lamps ranged from less than 1 percent to more than 3 percent as lethal as sunlight while the sunlamp was more than 4 times more lethal than sunlight

Additional details

Publishing Information

Imprint Title
Symposium on biological effects and measurement of light sources
Journal Page Range
p. 150-155.
Report number
FDA--81-8156

Conference

Title
Symposium on biological effects and measurement of light sources.
Dates
9 - 10 Jun 1980.
Place