Description
The Wolsong Unit 1 is a CANDU(CANadian Deuterium Uranium) reactor imported from Canada, which has been generated 2061.4 MW(th) and 678.7 MWe since April 1983. Because the design lifetime of this reactor is 30 years, KHNP(Korea Hydro Nuclear Power) Co. decided to operate the Wolsong Unit 1 continuously under the confirmation of safety and economic efficiency after the refurbishment. As a part of Refurbishment Project of the Wolsong Unit 1, the nuclear design part(Chapter 4.3) of FSAR(Final Safety Analysis Report) has been revised and re-written. This paper describes the NUCIRC single channel analysis model developed for evaluating the power coefficient of the Wolsong Unit 1
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2009 spring meeting of the KNS
- Dates
- 18-23 May 2009
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 40099637
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DESIGN; EFFICIENCY; SAFETY; SAFETY ANALYSIS; WOLSUNG-1 REACTOR
- Descriptors DEC
- CANDU TYPE REACTORS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; THERMAL REACTORS
Optional Information
- Notes
- 4 refs, 2 figs, 2 tabs