An examination on aseismatic design of civil engineering structures in nuclear power stations

  • 1. Chubu Electric Power Co. Inc., Nagoya (Japan)

Description

As for the aseismatic design of civil engineering structures in nuclear power stations, the basic way of thinking and the example design are shown in the technical guidelines and others, but when the aseismatic design is actually carried out, the techniques of aseismatic calculation and the modeling for structural analysis are left to the judgement of designers. Among such various problems, in this report, the applicability of response displacement method and response magnitude method as the aseismatic calculation techniques and the necessity of rigid region in rahmen members in structural analysis were examined, and those are described. As the structures in nuclear power stations, there are cooling water intake and discharge facilities, emergency water intake, breakwater, unloading quays, revetments, the foundations of tanks, machinery and equipment, piping and others, roads, bridges, tunnels and so on. The outline of their aseismatic design and the examination on the cases of aseismatic design are reported. These structures are frequently underground structures, which are different from those on the ground. (K.I.)

Additional details

Publishing Information

Journal Title
Denryoku Doboku
Journal Issue
no.225
Series
Denryoku Doboku.
ISSN
0386-2895
CODEN
DEDOD