Published January 1, 2016 | Version v1
Journal article

Development of radiation tolerant components for the Quench Protection System at CERN

  • 1. Technische Universitaet Darmstadt, Karolinenplatz 5, 64289 Darmstadt (Germany)
  • 2. CERN, 385 Route de Meyrin, 1217 Meyrin (Switzerland)

Description

This paper describes the results of irradiation campaigns with the high resolution Analog to Digital Converter (ADC) ADS1281. This ADC will be used as part of a revised quench detection circuit for the 600 A corrector magnets at the CERN Large Hadron Collider (LHC) . To verify the radiation tolerance of the ADC an irradiation campaign using a proton beam, applying doses up to 3,4 kGy was conducted. The resulting data and an analysis of the found failure modes is discussed in this paper. Several mitigation measures are described that allow to reduce the error rate to levels acceptable for operation as part of the LHC QPS

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/11/01/C01032

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
11
Journal Issue
01
Journal Page Range
p. C01032
ISSN
1748-0221