Verification of energy dependence of electron paramagnetic resonance(EPR) dosimeters

  • 1. Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

Description

This study was focused on the dependence of some EPR dosimetric materials under different electron energy range in order to identify those that could be suitable for low dose applications. The stopping power ratios for (Alanine, Magnesium formate, Potassium dithionate, Calcium sulfate, Barium sulphate, Lithium formate, Sodium carbonate, Strontium dithionate, Cesium dithionate and Ammonium formate) were calculated based on NIST-ESTAR program online database, which is the same as those tabulated in ICRU report 37, Xmudat software code was used to calculate the effective atomic number and density for each dosimeter. The results indicate that, EPR dosimeter with effective atomic number less than 16 could be suitable to be used at low dose applications with slightly correction to get the optimum value. The dosimeter with effective atomic number more than 16 showed large discrepancies in its values below 0.7 MeV and above 2 MeV, which indicate that in spite of the high sensitivity the dosimeter it might not be suitable to work at low dose range. (Author)

Availability note (English)

Also available from Sudan Atomic Energy Commission, Khartoum (SD)

Files

50015320.pdf

Files (3.3 MB)

Name Size Download all
md5:52fc0b812d4dc100eab67a5f0e070222
3.3 MB Preview Download

Additional details

Publishing Information

Imprint Place
Khartoum (Sudan)
Imprint Pagination
38 p.
Report number
INIS-SD--717

Optional Information

Notes
20 refs., 1 tab., 10 figs.