Published August 1995
| Version v1
Journal article
Performance of a large scale scintillating fiber tracker using VLPC readout
Creators
- 1. Rice Univ., Houston, TX (United States)
- 2. Univ. of Illinois, Chicago, IL (United States)
- 3. Univ. of Notre Dame, IN (United States)
Description
A large scale scintillating fiber tracker using visible light photon counter (VLPC) readout was built as a prototype for the upgraded D0 central tracker. This prototype has been under test at fermilab for six months using cosmic rays. A description of the components of the tracker including the photodetector, fibers, lightguides, ribbons, and DAQ is given. Preliminary results on detected photon yield, position resolution, efficiency and VLPC performance are presented
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 42
- Journal Issue
- 4Pt1
- Journal Page Range
- p. 401-408.
- ISSN
- 0018-9499
- CODEN
- IETNAE
Conference
- Title
- medical imaging conference.
- Acronym
- Nuclear science symposium
- Dates
- 30 Oct - 5 Nov 1994.
- Place
- Norfolk, VA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27015954
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COSMIC RADIATION; DESIGN; FERMILAB TEVATRON; MODIFICATIONS; PARTICLE TRACKS; PERFORMANCE; PERFORMANCE TESTING; PHOTODETECTORS; PLASTIC SCINTILLATION DETECTORS; RADIATION DETECTORS; READOUT SYSTEMS
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; RADIATIONS; SCINTILLATION COUNTERS; SOLID SCINTILLATION DETECTORS; SYNCHROTRONS; TESTING
Optional Information
- Secondary number(s)
- CONF-941061--.