Published August 1995 | Version v1
Journal article

Performance of a large scale scintillating fiber tracker using VLPC readout

  • 1. Rice Univ., Houston, TX (United States)
  • 2. Univ. of Illinois, Chicago, IL (United States)
  • 3. Univ. of Notre Dame, IN (United States)

Description

A large scale scintillating fiber tracker using visible light photon counter (VLPC) readout was built as a prototype for the upgraded D0 central tracker. This prototype has been under test at fermilab for six months using cosmic rays. A description of the components of the tracker including the photodetector, fibers, lightguides, ribbons, and DAQ is given. Preliminary results on detected photon yield, position resolution, efficiency and VLPC performance are presented

Additional details

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
42
Journal Issue
4Pt1
Journal Page Range
p. 401-408.
ISSN
0018-9499
CODEN
IETNAE

Conference

Title
medical imaging conference.
Acronym
Nuclear science symposium
Dates
30 Oct - 5 Nov 1994.
Place
Norfolk, VA (United States).

Optional Information

Secondary number(s)
CONF-941061--.