Compacted soil barriers at abandoned landfill sites are likely to fail in the long term
Creators
- 1. Oak Ridge National Lab., TN (United States)
Description
At innumerable sites in the USA and around the world, buried waste has been isolated from the environment by barriers constructed entirely or in part of compacted soil. The chief concern in barrier design has been to isolate the waste in the short term by preventing movement of water into and through the waste. However, in the long term a variety of mechanisms can act to compromise this isolation. The mechanisms of long-term failure include initial flaws in barrier construction, shrink-swell cycles, freeze-thaw cycles, erosion, subsidence, root intrusion, and animal intrusion. Evidence for action of all of these mechanisms is summarized. The likelihood of long-term failure suggests that either perpetual care must be provided for buried hazardous wastes, or the waste sites must be designed to withstand long-term threats to barrier integrity. 69 refs., 3 figs., 2 tabs
Additional details
Publishing Information
- Journal Title
- Journal of Environmental Quality
- Journal Volume
- 22
- Journal Issue
- 2
- Journal Page Range
- p. 217-226.
- ISSN
- 0047-2425
- CODEN
- JEVQAA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 25002523
- Subject category
- S54: ENVIRONMENTAL SCIENCES; S58: GEOSCIENCES;
- Descriptors DEI
- EROSION; GROUND SUBSIDENCE; HAZARDOUS MATERIALS; LINERS; SANITARY LANDFILLS; SOIL MECHANICS; SOIL-STRUCTURE INTERACTIONS; SYSTEM FAILURE ANALYSIS; UNDERGROUND DISPOSAL
- Descriptors DEC
- MANAGEMENT; MATERIALS; MECHANICS; SYSTEMS ANALYSIS; WASTE DISPOSAL; WASTE MANAGEMENT