Published August 15, 1978
| Version v1
Journal article
Precise determination of size and uniformity of a fissionable source
- 1. Institute of Nuclear Research, Warsaw (Poland)
Description
A method of determining the size and uniformity of the spontaneous fission source (or fissionable target) is presented. The position resolution of the method is of about 0.1 mm. (Auth.)
Additional details
Publishing Information
- Journal Title
- Nucl. Instrum. Methods
- Journal Volume
- 154
- Journal Issue
- 2
- Series
- Nucl. Instrum. Methods.
- Journal Page Range
- 405-406
- ISSN
- 0029-554X
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 10423971
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- FISSION FRAGMENT DETECTION; FISSION FRAGMENTS; POSITION SENSITIVE DETECTORS; RADIATION SOURCES; SIZE; SPATIAL RESOLUTION; SPONTANEOUS FISSION
- Descriptors DEC
- DECAY; FISSION; MEASURING INSTRUMENTS; NUCLEAR DECAY; NUCLEAR FRAGMENTS; NUCLEAR REACTIONS; RADIATION DETECTION; RADIATION DETECTORS; RESOLUTION