Published August 15, 1978 | Version v1
Journal article

Precise determination of size and uniformity of a fissionable source

  • 1. Institute of Nuclear Research, Warsaw (Poland)

Description

A method of determining the size and uniformity of the spontaneous fission source (or fissionable target) is presented. The position resolution of the method is of about 0.1 mm. (Auth.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
154
Journal Issue
2
Series
Nucl. Instrum. Methods.
Journal Page Range
405-406
ISSN