The objective of this work was to study new possibilities for using oxalic acid aqueous solutions in chemical dosimetry of high absorption doses and propose procedures for routine application in gamma and reactor radiation dosimetry. Proportionality factors related to reactor radiation had to be specified by calorimetry measurements. Another task was to study the mechanism of oxalic acid aqueous solutions radiolysis under dosimetry irradiation conditions, especially for reaction which are significant for good reproduction of measurements

Availability note (English)

Available from the Institute of nuclear sciences Vinca

Additional details

Additional titles

Original title (Serbian)
Nove mogucnosti za rutinsku primenu vodenih rastvora oksalne kiseline u dozimetriji visokih apsorbovanih doza gama- i reaktorskog zracenja

Publishing Information

Publisher
Institute of Nuclear Sciences Boris Kidric
Imprint Place
Beograd (Yugoslavia)
Imprint Pagination
187 p.

Optional Information

Notes
140 refs, 28 figs, 30 tabs
Funding organization
Tehnolosko-metalurski fakultet, Univerzitet u Beogradu, Beograd (Yugoslavia)