Published 1993 | Version v1
Miscellaneous

Potential drop crack measurement systems for CANDU components

Creators

  • 1. Carleton Univ., Ottawa, ON (Canada)

Description

A project to develop an automated crack measurement system for CANDU pressure tube burst testing is currently underway. The system will utilize either Direct Current Potential Drop (DCPD) or Alternating Current Potential Drop (ACPD) techniques for crack measurement. The preliminary stage of the project involves testing and comparison of both ACPD and DCPD methods on a Zr - 2.5% Nb alloy plate with saw cuts (used to simulate cracks). Preliminary results show that both ACPD and DCPD techniques are capable of detecting cracks; further testing is in progress to determine the ability of each of the two systems to make accurate crack depth measurements. This paper will describe the two potential drop techniques and will present test results from the experimental program. (author). 10 refs., 7 figs

Part of:
Proceedings of the 18. annual student conference CNA/CNS

Additional details

Publishing Information

Imprint Title
Proceedings of the 18. annual student conference CNA/CNS
Imprint Pagination
239 p.
Journal Page Range
p. 88-100.
Report number
INIS-CA--0009

Conference

Title
18. Annual student conference CNA/CNS.
Dates
2-3 Apr 1993.
Place
Montreal, PQ (Canada).

Optional Information