Diagnostic accuracy of MRI in adults with suspect brachial plexus lesions: A multicentre retrospective study with surgical findings and clinical follow-up as reference standard
- 1. Institute of Anatomy, Department of Experimental Medicine, University of Genoa, Largo Rosanna Benzi 8, 16132 Genoa (Italy)
- 2. Department of Radiology, Santa Corona Hospital, Pietra Ligure, Italy via XXV Aprile, 38- Pietra Ligure, 17027 Savona (Italy)
- 3. Radiology Department, DISC, Università di Genova, Largo Rosanna Benzi 8, 16138 Genova (Italy)
Description
Objective: To evaluate brachial plexus MRI accuracy with surgical findings and clinical follow-up as reference standard in a large multicentre study. Materials and methods: The research was approved by the Institutional Review Boards, and all patients provided their written informed consent. A multicentre retrospective trial that included three centres was performed between March 2006 and April 2011. A total of 157 patients (men/women: 81/76; age range, 18–84 years) were evaluated: surgical findings and clinical follow-up of at least 12 months were used as the reference standard. MR imaging was performed with different equipment at 1.5 T and 3.0 T. The patient group was divided in five subgroups: mass lesion, traumatic injury, entrapment syndromes, post-treatment evaluation, and other. Sensitivity, specificity with 95% confidence intervals (CIs), positive predictive value (PPV), pre-test-probability (the prevalence), negative predictive value (NPV), pre- and post-test odds (OR), likelihood ratio for positive results (LH+), likelihood ratio for negative results (LH−), accuracy and post-test probability (post-P) were reported on a per-patient basis. Results: The overall sensitivity and specificity with 95% CIs were: 0.810/0.914; (0.697–0.904). Overall PPV, pre-test probability, NPV, LH+, LH−, and accuracy: 0.823, 0.331, 0.905, 9.432, 0.210, 0.878. Conclusions: The overall diagnostic accuracy of brachial plexus MRI calculated on a per-patient base is relatively high. The specificity of brachial plexus MRI in patients suspected of having a space-occupying mass is very high. The sensitivity is also high, but there are false-positive interpretations as well
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2011.10.007Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2011.10.007;
- PII
- S0720-048X(11)00731-5;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 10
- Journal Page Range
- p. 2666-2672
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Cuba
- INIS RN
- 45043864
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ADULTS; DATA; EQUIPMENT; EVALUATION; INJURIES; MEN; NMR IMAGING; PATIENTS; PROBABILITY; SENSITIVITY; SPECIFICITY; STANDARDS; SURGERY; WOMEN
- Descriptors DEC
- AGE GROUPS; ANIMALS; DIAGNOSTIC TECHNIQUES; DISEASES; FEMALES; INFORMATION; MALES; MAMMALS; MAN; MEDICINE; PRIMATES; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.