Published April 2008 | Version v1
Journal article

An active-passive beam current transformer

  • 1. National Synchrotron Radiation Laboratory, Univ. of Science and Technology of China, Hefei (China)

Description

In this article, a new type current transformer was developed using an active-passive circuit to improve low frequency response of the system without impairing high frequency response. The active-passive current transformer with In-flange was fabricated. Theoretical analysis, numerical simulations and experimental results are given. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Science and Techniques
Journal Volume
19
Journal Issue
2
Journal Page Range
p. 70-73
ISSN
1001-8042

Optional Information

Notes
8 figs., 6 refs.