Published July 1987 | Version v1
Journal article

Measurement and calculation of shunt impedance for coupled cavity chain

Creators

  • 1. Beijing Medical Equipment Inst. (China)

Description

The shunt impedance of coupled cavity chain which is normally smaller than that of single cavity in the chain should be measured and calculated. A formula for direct calculating the shunt impedance ZT2 of the coupled cavity chain is presented according to analysis on the interaction between charged particles and electric field of cylindrical symmetry. The formula is a gencral form for calculating shunt impedance, which is also valid for single cavity. The method and results of experiment by using the formula are given, the results obtained here are identical with that of Koichi Irie's formula

Additional details

Publishing Information

Journal Title
At. Energy Sci. Technol.
Journal Volume
21
Journal Issue
4
Series
At. Energy Sci. Technol.
Journal Page Range
494-496
CODEN
YKJIE

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
19055426
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
CAVITY RESONATORS; EIGENFREQUENCY; ELECTRIC FIELDS; FREQUENCY RANGE; IMPEDANCE; Q-VALUE; RESONANCE; STANDING WAVES
Descriptors DEC
ELECTRONIC EQUIPMENT; ENERGY; EQUIPMENT; RESONATORS