Position encoder

  • 1. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Services d'Electronique

Description

A circuitry for deriving the quotient of signal delivered by position-sensitive detectors is described. Digital output is obtained in the form of 10- to 12-bit words. Impact position may be determined with 0.25% accuracy when the dynamic range of the energy signal is less 1:10, and 0.5% accuracy when the dynamic range is 1:20. The division requires an average time of 5μs for 10-bit words

Additional details

Publishing Information

Imprint Title
Proceedings 2nd Ispra nuclear electronics symposium. Stresa, Italy, May 20-23, 1975
Imprint Pagination
p. 25-28.
Report number
EUR--5370

Conference

Title
2. Ispra nuclear electronics symposium.
Dates
20 May 1975.
Place
Stresa, Italy.

INIS

Country of Publication
European Commission (EC), Brussels (Belgium)
Country of Input or Organization
European Commission (EC), Brussels (Belgium)
INIS RN
7249372
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANALOG SYSTEMS; DATA ACQUISITION SYSTEMS; ELECTRONIC CIRCUITS; NUCLEAR INSTRUMENT MODULES; PERFORMANCE; POSITION SENSITIVE DETECTORS; PROPORTIONAL COUNTERS; SIGNALS; TIMING PROPERTIES
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS