Published 1996
| Version v1
Miscellaneous
Pharyngeal transit time measured by scintigraphic and biomagnetic method
- 1. Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica
- 2. Faculdade de Medicina de Ribeirao Preto, SP (Brazil)
Description
A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with 99m Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution
Additional details
Additional titles
- Original title (Portuguese)
- Tempo de transito faringeano medido atraves dos metodos cintilografico e biomagnetico
Publishing Information
- Imprint Title
- Proceedings of the 3. Brazilian forum on health science and technology; 15. Brazilian congress on biomedical engineering; 6. Brazilian congress of physicists in medicine; 5. Brazilian congress of informatics in health; Brazilian meeting on radiological protection. v. 1
- Imprint Pagination
- 445 p.
- Journal Page Range
- p. 99-100
Conference
- Title
- 3. Brazilian forum on health science and technology; 15. Brazilian congress on biomedical engineering; 6. Brazilian congress of physicists in medicine; 5. Brazilian congress on informatics in health; Brazilian meeting on radiological protection
- Original Conference Title
- 3. Forum nacional de ciencia e tecnologia em saude
- Dates
- 13-17 Oct 1996
- Place
- Campos de Jordao, SP (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 29057626
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPARATIVE EVALUATIONS; DIAGNOSIS; DIGESTIVE SYSTEM; FERRITE; LABELLING; MAGNETIC MATERIALS; PHARYNX; SCINTISCANNING; TECHNETIUM 99; TIME DEPENDENCE
- Descriptors DEC
- ALLOYS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARBON ADDITIONS; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EVALUATION; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IRON ALLOYS; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MATERIALS; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIOISOTOPE SCANNING; RADIOISOTOPES; RESPIRATORY SYSTEM; TECHNETIUM ISOTOPES; TRANSITION ELEMENT ALLOYS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 3 refs., 2 figs., 1 tab. Imprint:Anais do 3. Forum nacional de ciencia e tecnologia em saude; 15. Congresso brasileiro de engenharia biomedica; 6. Congresso brasileiro de fisicos em medicina; 5. Congresso brasileiro de informatica em saude; Encontro brasileiro de protecao radiologica