Use of gradient dilution to flag and overcome matrix interferences in axial-viewing inductively coupled plasma-atomic emission spectrometry
Description
Despite the undisputed power of inductively coupled plasma-atomic emission spectrometry (ICP-AES), its users still face serious challenges in obtaining accurate analytical results. Matrix interference is perhaps the most important challenge. Dilution of a matrix-containing sample is a common practice to reduce matrix interference. However, determining the optimal dilution factor requires tedious and time-consuming offline sample preparation, since emission lines and the effect of matrix interferences are affected differently by the dilution. The current study exploits this difference by employing a high-performance liquid chromatography gradient pump prior to the nebulizer to perform on-line mixing of a sample solution and diluent. Linear gradient dilution is performed on both the calibration standard and the matrix-containing sample. By ratioing the signals from two emission lines (from the same or different elements) as a function of dilution factor, the analyst can not only identify the presence of a matrix interference, but also determine the optimal dilution factor needed to overcome the interference. A ratio that does not change with dilution signals the absence of a matrix interference, whereas a changing ratio indicates the presence of an interference. The point on the dilution profile where the ratio stabilizes indicates the optimal dilution factor to correct the interference. The current study was performed on axial-viewing ICP-AES with o-xylene as the solvent
Availability note (English)
Available from http://dx.doi.org/10.1016/j.sab.2014.05.014Additional details
Identifiers
- DOI
- 10.1016/j.sab.2014.05.014;
- PII
- S0584-8547(14)00178-5;
Publishing Information
- Journal Title
- Spectrochimica Acta. Part B, Atomic Spectroscopy
- Journal Volume
- 100
- Journal Page Range
- p. 38-43
- ISSN
- 0584-8547
- CODEN
- SAASBH
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47009029
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- AUGER ELECTRON SPECTROSCOPY; CALIBRATION STANDARDS; DILUTION; EMISSION SPECTROSCOPY; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; ICP MASS SPECTROSCOPY; INTERFERENCE; MATRIX MATERIALS; MULTI-ELEMENT ANALYSIS; ORGANIC SOLVENTS; PLASMA; QUANTITATIVE CHEMICAL ANALYSIS; SAMPLE PREPARATION; XYLENES
- Descriptors DEC
- ALKYLATED AROMATICS; AROMATICS; CHEMICAL ANALYSIS; CHROMATOGRAPHY; ELECTRON SPECTROSCOPY; HYDROCARBONS; LIQUID COLUMN CHROMATOGRAPHY; MASS SPECTROSCOPY; MATERIALS; NONAQUEOUS SOLVENTS; ORGANIC COMPOUNDS; SEPARATION PROCESSES; SOLVENTS; SPECTROSCOPY; STANDARDS
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.