Published August 1999 | Version v1
Journal article

Steam generator replacement at Ikata nuclear power plant Unit-1

  • 1. Shikoku Electric Power Co., Inc., Takamatsu (Japan)

Description

Steam Generator is one of the most important components in PWR power plant. Since the heat transfer tube experienced degradation, Steam Generator Replacement has been performed in 9 units in Japan, as a result of comprehensive considerations including public confidence, maintainability and economic efficiency. This report presents mainly the technical features specifically applied to SGR work of Ikata Unit-1, latest SGR project, in which we adopted ultra-heavy crawler crane to carry in and out SGs and 2 cut method to cut and weld Main Coolant Pipes. (author)

Additional details

Publishing Information

Journal Title
Dekomisshoningu Giho
Journal Issue
no.20
Journal Page Range
p. 11-20
ISSN
1343-3881