Published 2009 | Version v1
Journal article

Manufacturing and Test of a Short Nb3Sn Quadrupole Magnet Model at CEA/Saclay

  • 1. CEA, DSM, IRFU, SACM, Ctr Saclay, F-91191 Gif Sur Yvette, (France)

Description

Applications in MRI and NMR need higher fields to improve imaging performances. For such high field magnets, it is sometimes necessary to operate them in driven mode. However, the NMR and MRI requires a field drift of less than the best power supply can make (typically, MRI need less than 0.05 ppm/hr and NMR is more demanding, in comparison best stabilized power supply have drift of about 1 ppm/hr). A solution had been found in literature: a semi persistent mode with a resistance (R1) connected in parallel with the magnet and to the power supply, filters the power supply drift. But it is not sufficient for application in large magnet. In fact, in case of quench, energy contained in the magnet will destroy the resistance in parallel to the magnet because its value is too small. A discharge resistance in parallel to the magnet and to the resistance R1 is necessary and a switch in series with the resistance R1 is opened when a quench is detected. During the quench, the voltage on the switch could be large. An alternative of a switch is a fault current limiter which is usually used for the protection of an electrical network (it limits fault current) and to increase its quality. A study has been done to verify the feasibility of this object and an experimental assessment has been done on a very small magnet operating at 7 T using a prototype of fault current limiter made of 100 meters of superconducting wire. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1109/TASC.2009.2017829

Additional details

Identifiers

Publishing Information

Journal Title
IEEE Transactions on Applied Superconductivity (Print)
Journal Volume
19
Journal Issue
no.3
Journal Page Range
p. 1121-1124
ISSN
1051-8223

Optional Information

Notes
8 refs.