Published May 2003 | Version v1
Miscellaneous Open

Fuel management of the compact core 15 MW RSG-GAS using Silicide fuel

  • 1. Center for Development of Research Reactor Technology (Indonesia)

Description

The RSG-GAS is operating at 15 MW power level now and it's suitable to user need. Based on efficiency it is needed to know the fuel management of RSG-GAS for 15 MW power level. In this research, it is done the core configuration of the 15 MW taking four fuels out from 40 to 36 fuels using CIP and without CIP. This way is done because if the 30 MW core configuration is needed it is easy to change again. From the result of calculation showed that the core using CIP core can operated 530 MWD. But without CIP can be operated 600 MWD with discharge maximum burn-up 60 %

Files

38115346.pdf

Files (247.8 kB)

Name Size Download all
md5:001aca00ee469f8cb0300cdc67e2e75a
247.8 kB Preview Download
Part of:
Proceeding of the Seminar Result of Research Reactor Safety Technology Research Centre

Additional details

Additional titles

Original title (Indonesian)
Pembentukan teras kompak 15 MW RSG-GAS berbahan bakar Silisida

Publishing Information

Publisher
National Nuclear Energy Agency
Imprint Place
Serpong (Indonesia)
Imprint Title
Proceeding of the Seminar Result of Research Reactor Safety Technology Research Centre
Imprint Pagination
235 p.
Journal Page Range
p. 129-135
ISSN
0854-5278
Report number
INIS-ID--038

Conference

Title
Seminar Result of Research Reactor Safety Technology Research Centre 2002
Original Conference Title
Seminar Hasil Penelitian P2TRR tahun 2002
Dates
4-5 Feb 2003
Place
Serpong (Indonesia)

Optional Information

Notes
5 refs; 2 tabs; 4 figs Imprint:Prosiding Seminar Hasil Penelititan P2TRR Tahun 2002