The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors
Creators
- 1. Radiotherapiegroep, Arnhem (Netherlands)
- 2. Department of Urology, Rijnstate Hospital, Arnhem (Netherlands)
Description
Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2016.03.029Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2016.03.029;
- PII
- S0360-3016(16)00341-2;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 95
- Journal Issue
- 5
- Journal Page Range
- p. 1439-1442
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48097359
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLADDER; BRACHYTHERAPY; EXTERNAL IRRADIATION; GY RANGE 01-10; GY RANGE 10-100; LYMPH NODES; NEOPLASMS; PATIENTS; RISK ASSESSMENT; ROBOTS; SCHEDULES; TOXICITY
- Descriptors DEC
- ABSORBED DOSE RANGE; BODY; DISEASES; EQUIPMENT; GY RANGE; IRRADIATION; LYMPHATIC SYSTEM; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; THERAPY; URINARY TRACT
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.