Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers?
Creators
- 1. Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)
- 2. Siemens AG, H IM SYNGO CAD Research and Development, Malvern, PA (United States)
- 3. Seoul Medical Center, Department of Radiology, Seoul (Korea, Republic of)
- 4. University of Navarra, Department of Radiology, Pamplona (Spain)
- 5. Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)
Description
To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ2 and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-010-2050-xAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 21
- Journal Issue
- 6
- Journal Page Range
- p. 1214-1223
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 42082202
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; EMBOLI; LAVAGE; LUNGS; SENSITIVITY; STATISTICS; VASCULAR DISEASES
- Descriptors DEC
- BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MATHEMATICAL LOGIC; MATHEMATICS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; TOMOGRAPHY