Published November 15, 1984 | Version v1
Journal article

Cathode readout multiwire proportional chamber for ISTRA setup

Description

The main characteristics of cathode readout multiwire proportional chambers with 760 x 760 mm2 active area are presented for particle loads up to 103 part./mm2xs. The following chamber characteristics were obtained: efficiency, epsilon = 99%, space resolution, delta = 0.3 mm, rms of charge ratio Qsub(x)/Qsub(Y) for charges on the X- and Y-plane of one chamber deltasub(QX/QY) = 7%. A description is given of chamber design and operation, calibration and detector check-up procedures, and registered charged particle coordinate reconstruction methods. Calculated dependencies for the probability of obtaining the true multitrack event coordinate on the deltasub(QX/QY) value are presented. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
227
Journal Issue
2
Series
CODEN: NIMRD.;Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
242-248
ISSN
0167-5087