Modification and optimization of narrow range temperature probe in CPR1000 unit
- 1. China Nuclear Power Co., Ltd., Shenzhen (China)
Description
With the extension of the operation period, the characteristics of narrow range temperature probe will be drifting and aging in CPR1000 units. At the same time, the change of thermal hydraulic characteristics factors will also lead to the unreasonable setting of the parameters of average temperature summary and temperature deviation summary. Therefore, it requires to modify the characteristics of narrow range temperature probe and the parameters of summary according to the cross comparison data. Aiming at the possible deviation, the modification method is put forward: the fitting modification method for three point curve of narrow range temperature probe and the fitting modification of two point curve of the average temperature summary and temperature deviation summary. And the optimization and improvement scheme is put forward, including excluding natural temperature deviation factor, weight coefficient in different operation conditions and horizontal/vertical trend comparison. These methods had been applied in the field, and were proved to be feasible and effective. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 36
- Journal Issue
- 1
- Journal Page Range
- p. 108-112
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 48083736
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CHINA; MEASURING INSTRUMENTS; MODIFICATIONS; NUCLEAR POWER PLANTS; PWR TYPE REACTORS; TEMPERATURE MEASUREMENT
- Descriptors DEC
- ASIA; ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 2 figs., 9 refs.