Published 1986 | Version v1
Book

U-tube steam generator model validation for system fault analysis

  • 1. Electricite de France, 78 - Chatou. Service d'Etudes et Recherches Nucleaires, Thermiques et Hydrauliques
  • 2. Electricite de France, 75 - Paris. Service de la Production Thermique

Description

In this paper, the modelling of dynamics of a U - tube steam generator is considered. This U - tube steam generator model (GEVAP) is used in a process fault detection based on modelling method (reference model). The main results of the studies of the model's transients are presented. Identification and validation of some of the model's parameters on the basis of experimental data is described and discussed. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London (UK)
ISBN
0 7277 0269 6
Imprint Title
Boiler dynamics and control in nuclear power stations 3
Imprint Pagination
342 p.
Journal Page Range
p. 231-235.

Conference

Title
3. international conference on boiler dynamics and control in nuclear power stations.
Dates
21-25 Oct 1985.
Place