Published 1975 | Version v1
Book

Some optical devices for inspection within graphite moderated reactors

Creators

  • 1. Central Electricity Generating Board, Bristol (UK)

Description

A number of tools for the optical inspection of graphite moderated reactors are described. A 51mm diameter zoom television camera can be used with attachments for; tube inspection; multidirectional illuminating and viewing; and illuminating and viewing transversely at distances up to 8m. Single and twin zoom television cameras for multidirectional imaging of the above-core reactor internals are designed to view to the side of obstructing standpipe assemblies. A photographic camera of 60mm format is also described for viewing above-core reactor internals by one of a number of lenses and assisted by a television reflex viewfinder and focusing aid. (author)

Additional details

Additional titles

Subtitle (English)
Paper 6

Publishing Information

Publisher
T. Telford Ltd for the British Nuclear Energy Society.
Imprint Place
London
ISBN
0727700111
Imprint Title
Symposium on reactor inspection technology, Bristol, 26 February 1975
Imprint Pagination
12 p.

Conference

Title
Symposium on reactor inspection technology.
Dates
26 Feb 1975.
Place
Bristol, UK.

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
7231121
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAMERAS; GRAPHITE MODERATED REACTORS; INSPECTION; OPTICAL SYSTEMS; PHOTOGRAPHY; REACTOR COMPONENTS; REMOTE VIEWING EQUIPMENT; TELEVISION
Descriptors DEC
REACTORS