Published 1987 | Version v1
Miscellaneous

Maintainability of CANDU 300

  • 1. Atomic Energy of Canada Ltd., Sheridan Park, ON (Canada). CANDU Operations

Description

This paper discusses the provisions for maintainability and replacement which have been incorporated into the CANDU 300. Plant layout, building layouts, zoning, maintenance building design, and in-service inspection plans are described. Process system maintainability and equipment removal paths are described. Replacement of components other than fuel channels and steam generators can generally be accommodated within a routine outage. The 232 fuel channels can be replaced in 92 days

Part of:
Proceedings of the Canadian Nuclear Society CANDU maintenance conference

Additional details

Publishing Information

ISBN
0-919784-15-1
Imprint Title
Proceedings of the Canadian Nuclear Society CANDU maintenance conference
Imprint Pagination
342 p.
Journal Page Range
p. 3B.26-3B.31.
Report number
INIS-mf--13763

Conference

Title
CANDU maintenance conference.
Dates
22-24 Nov 1987.
Place
Toronto, ON (Canada).

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
25010875
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CANDU TYPE REACTORS; DESIGN; FUEL CHANNELS; REACTOR MAINTENANCE; SPECIFICATIONS
Descriptors DEC
HEAVY WATER MODERATED REACTORS; MAINTENANCE; POWER REACTORS; PRESSURE TUBE REACTORS; REACTOR CHANNELS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS

Optional Information