Means of high-energy radiation diagnosis of industrial products
Description
The radiation microtron flaw detector RMD-10T for the nondestructive control of welded joints and the main metal up to 400 mm thick is developed and introduced. Its compactness and mobility convenience and reliability are its main positive features. The original design of a high-frequency tract is located on the microtron electromagnetic bond. Its sensitivity is not worse than 1%. The productivity is 10-20 times higher than in analogous devices. The electroradiographic isotopic flaw detector EhRIO-01 for the control of a complex-shape steel sheet with a 60Co radiation source and up to 2.5% sensitivity has been successfully tested
Additional details
Additional titles
- Original title (Russian)
- Средства зысокоэнергетической радиационной диагностики промышленных изделий
Publishing Information
- Journal Title
- Pribory i Sistemy Upravleniya
- Journal Issue
- no.8
- Series
- Prib. Sist. Upr.
- ISSN
- 0032-8154
- CODEN
- PSUPB
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 21083286
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- COBALT 60; CONTROL SYSTEMS; EFFICIENCY; INDUSTRIAL RADIOGRAPHY; MICROTRONS; OPTIMIZATION; RADIATION SOURCES; SENSITIVITY; THICKNESS; WELDED JOINTS; X-RAY EMISSION ANALYSIS
- Descriptors DEC
- ACCELERATORS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CHEMICAL ANALYSIS; COBALT ISOTOPES; CYCLIC ACCELERATORS; CYCLOTRONS; DIMENSIONS; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; JOINTS; MATERIALS TESTING; MINUTES LIVING RADIOISOTOPES; NONDESTRUCTIVE ANALYSIS; NONDESTRUCTIVE TESTING; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; TESTING; YEARS LIVING RADIOISOTOPES