Description

For the evaluation of right ventricular ejection fraction (RVEF) using krypton-81m perfusion, the following findings were emphasized: the effect of lung background subtraction; the bad reproducibility of RVEF determination by two different observers; the good reproducibility of RVEF determination by the same observer; the good reproducibility of RVEF determination in the same patient

Abstract (French)

Pour la mesure de la fraction d'ejection du ventricule droit (FEVD) a l'aide dune perfusion de krypton 81m, l'etude a montre: l'interet de soustraire le bruit de fond pulmonaire (BFP); une mauvaise reproductibilite des mesures de la FEVD par deux observateurs differents; une bonne reproductibilite des mesures de la FEVD par un meme observateur; une bonne reproductibilite des mesures de la FEVD chez un meme patient

Additional details

Additional titles

Original title (French)
Mesure de la fraction d'ejection du ventricule droit avec une perfusion de Krypton 81m: methodologie