Published August 1986 | Version v1
Journal article

Toroidal variation of power radiated from TFTR

  • 1. Princeton University, Plasma Physics Laboratory, Princeton, New Jersey 08544

Description

Bolometers located at a number of toroidal and poloidal positions are used to determine the toroidal distribution of impurity radiation losses from the Tokamak Fusion Test Reactor (TFTR) plasmas. Distributions for both OH and beam-heated D+ and He++ plasmas have been determined. The distributions are highly peaked at the limiter sector for plasmas run on the outer limiter but more symmetric toroidally when run on the inner bumper limiter. Plasmas detached from both inner and outer limiters have distributions which are basically symmetric toroidally and poloidally. The widths of toroidally peaked distributions are < or =1 sector of the 20 sector torus. Scalings of the enhanced radiative losses at the limiter with input power are indicated

Additional details

Publishing Information

Journal Title
Rev. Sci. Instrum.
Journal Volume
57
Journal Issue
8
Series
Rev. Sci. Instrum.
Journal Page Range
2078-2080
ISSN
0034-6748
CODEN
RSINA

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17079973
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
BOLOMETERS; DEUTERONS; HELIUM IONS; HYDROXYL RADICALS; IMPURITIES; LIMITERS; PLASMA DIAGNOSTICS; TFTR TOKAMAK
Descriptors DEC
CHARGED PARTICLES; CLOSED PLASMA DEVICES; IONS; MEASURING INSTRUMENTS; RADICALS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES