Published June 1992 | Version v1
Report

Absorbed dose measurements and predictions on LDEF

  • 1. Science Applications International Corp., Prospect, TN (United States)

Description

The overall radiation environment of LDEF was determined in part through the use of thermoluminescent detectors (TLDs). The results given are from four experiments (Biostack, Fiber Optics Data Link, Seeds in Space, and Linear Energy Transfer Spectrum Measurement) and represent a large fraction of existing absorbed dose data. The TLDs (located on leading and trailing edges) were under various shielding depths. The measured absorbed doses were found to reflect both directional dependence of incident trapped protons and shielding. Radiation dosages at both locations and under various shielding depths are given. The effect of the trapped proton anisotropy was such that the western side of LDEF received about 3 times the dose of the eastern side at shielding depths of approx. 1 gm/sq cm. These data are being used to evaluate the accuracy of models currently in use for predicting ionizing radiation environments for low Earth orbit missions

Additional details

Publishing Information

Imprint Title
Second LDEF Post-Retrieval Symposium abstracts
Imprint Pagination
133 p.
Journal Page Range
p. 18.
Report number
N--92-27218

Conference

Title
2. Long Duration Exposure Facility (LDEF) post-retrieval symposium.
Dates
1-5 Jun 1992.
Place
San Diego, CA (United States).

Optional Information

Contract/Grant/Project number
Contract NAS8-38610
Notes
Imprint:Abstract Only.
Secondary number(s)