On thermal losses in the high temperature blanket of a thermonuclear reactor

Description

A simple mathematical model is presented which allows to evaluate the optimal thermal insulation parameters and thermal losses from the high temperature blanket of a thermonuclear reactor into the cooling circuits of relatively ''cold'' elements of the plant, e.g. of the first wall. The effect of such parameters as insulation thickness and temperature on the level of thermal losses is illustrated by the numerical data. The use of highly effective thermal insulation of the optimum thickness is shown to be necessary

Availability note (English)

MF available from INIS under the Report Number.

Files

10419676.pdf

Files (366.8 kB)

Name Size Download all
md5:85e50ed320694ec74598f0fb178d2c5b
366.8 kB Preview Download

System files (49.7 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
О тепловых потерях в высокотемпературном бланкете термоядерного реакотра

Publishing Information

Imprint Pagination
16 p.
Report number
IAE--2881

Optional Information

Notes
3 refs.; 10 figs.; 1 table.