Published 1986 | Version v1
Book

Installation and calibration of a grating spectrometer for electron cyclotron emission measurements using circular waveguide

  • 1. GA Technologies, Inc., Oak Ridge, TN (USA)

Description

The grating spectrometer installation on the DIII-D tokamak is discussed. It uses fundamental circular waveguide propagating the TE11 lowest order mode followed by oversized circular guide carrying the low loss TE01 mode. The short section of fundamental guide permits use of an electronic chopper operating at 50 kHz for both calibration and plasma operation. By using a.c.-coupled amplifiers tuned to the chopping frequency, the background signal generated in the InSb detectors by neutrons and x-rays is automatically subtracted and the system noise bandwidth is reduced. Compared with a quasi-optical system, the much smaller fundamental horn and front end waveguide allow the entire waveguide system to be located outside a gate valve. With this configuration the entire waveguide run, including the actual horn and vacuum window used during plasma operations, can be included in the calibration set-up

Additional details

Publishing Information

Publisher
Princeton Plasma Physics Laboratory.
Imprint Place
Princeton, NJ (USA)
Imprint Title
Proceedings of the 6th topical conference on high temperature plasma diagnostics
Imprint Pagination
92 p.
Journal Page Range
p. H1.

Conference

Title
6. topical conference on high temperature plasma diagnostics.
Dates
9-13 Mar 1986.
Place
Hilton Head Island, SC (USA).

Optional Information

Secondary number(s)
CONF-860324--.