Published 1979 | Version v1
Report Restricted

Comparative analysis of a hypothetical transient over power accident in a LMFBR using different computer models for a common Benchmark problem

Description

Results from a comparative analysis of the initiating and disassembly phase of a hypothetical LMFBR over power accident are presented. The initiating fault was a reactivity ramp. The analyses were carried out for a common Benchmark problem with five different computer models (CAPRI/KADIS, CARMEN/KADIS, EAC/VENUS, FRAX/VENUS, SES/EPIC). Steady state and transient conditions before and after FCI initiation and during disassembly are compared. Differencies in the models for FCI and disassembly simulation are discussed. Assumptions and conditions for the calculations were made intentionally such that the accident would enter an energetic hydrodynamic disassembly phase

Availability note (English)

Available from CEC, BP 1003, Luxembourg.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
161 p.
Report number
EUR--6318

INIS

Country of Publication
European Commission (EC), Brussels (Belgium)
Country of Input or Organization
European Commission (EC), Brussels (Belgium)
INIS RN
12585909
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
BENCHMARKS; C CODES; E CODES; F CODES; FUEL-COOLANT INTERACTIONS; LMFBR TYPE REACTORS; REACTOR SAFETY; S CODES; SIMULATION; TRANSIENT OVERPOWER ACCIDENTS
Descriptors DEC
ACCIDENTS; BREEDER REACTORS; COMPUTER CODES; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; LIQUID METAL COOLED REACTORS; REACTOR ACCIDENTS; REACTORS; SAFETY