Published 1979
| Version v1
Report
Restricted
Comparative analysis of a hypothetical transient over power accident in a LMFBR using different computer models for a common Benchmark problem
Description
Results from a comparative analysis of the initiating and disassembly phase of a hypothetical LMFBR over power accident are presented. The initiating fault was a reactivity ramp. The analyses were carried out for a common Benchmark problem with five different computer models (CAPRI/KADIS, CARMEN/KADIS, EAC/VENUS, FRAX/VENUS, SES/EPIC). Steady state and transient conditions before and after FCI initiation and during disassembly are compared. Differencies in the models for FCI and disassembly simulation are discussed. Assumptions and conditions for the calculations were made intentionally such that the accident would enter an energetic hydrodynamic disassembly phase
Availability note (English)
Available from CEC, BP 1003, Luxembourg.
Files
Additional details
Publishing Information
- Imprint Pagination
- 161 p.
- Report number
- EUR--6318
INIS
- Country of Publication
- European Commission (EC), Brussels (Belgium)
- Country of Input or Organization
- European Commission (EC), Brussels (Belgium)
- INIS RN
- 12585909
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- BENCHMARKS; C CODES; E CODES; F CODES; FUEL-COOLANT INTERACTIONS; LMFBR TYPE REACTORS; REACTOR SAFETY; S CODES; SIMULATION; TRANSIENT OVERPOWER ACCIDENTS
- Descriptors DEC
- ACCIDENTS; BREEDER REACTORS; COMPUTER CODES; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; LIQUID METAL COOLED REACTORS; REACTOR ACCIDENTS; REACTORS; SAFETY