Rapid bacteria-detection platform based on magnetophoretic concentration, dielectrophoretic separation, and impedimetric detection

  • 1. School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, 61005 (Korea, Republic of)
  • 2. Department of Biomedical Science and Engineering, GIST, Gwangju, 61005 (Korea, Republic of)

Description

Most biosensors employ small sample quantities (less than 100 μL) for bacteria detection, thereby resulting in inaccurate low-concentration measurements. Detection performed using small sample volumes with low bacteria concentration may produce false-negative results. Therefore, sample pretreatment plays a critical role in accurate bacteria detection. This paper presents an impedimetric bacteria-detection sensor integrated with bacteria concentration and separation devices for rapid bacteria detection. Post conjugation using magnetic particles (MPs), the MP-conjugated bacteria (MP/Bac) are concentrated via magnetophoresis by a factor exceeding 100. In addition, MP/Bac are separated from MPs via dielectrophoresis to prevent occurrence of signal errors caused by MPs not conjugated with bacteria. Subsequently, concentrated MP/Bac are captured on a sensor electrode, and bacteria concentration is detected by measuring signal changes caused by the impedance difference between bacteria and the medium. The performance of the proposed bacteria-detection device was evaluated using a 5-mL homogenized cabbage sample injected with Staphylococcus aureus at 30 mL/h flow rate. The observed signal change was measured for 10 min using a sample with a concentration of 5–5 × 103 CFU/mL and was found to be approximately 0.34 mV at 50 CFU/mL; the limit of detection was 36 CFU/mL. These results confirm that the proposed device can detect low bacteria concentrations in food samples.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2021.338696

Additional details

Identifiers

DOI
10.1016/j.aca.2021.338696;
PII
S0003267021005225;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
1173
Journal Page Range
vp.
ISSN
0003-2670
CODEN
ACACAM

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
53096751
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
BRASSICA; CONCENTRATION RATIO; DETECTION; ELECTRODES; ERRORS; FLOW RATE; PARTICLES; PERFORMANCE; SENSORS; SIGNALS; STAPHYLOCOCCUS
Descriptors DEC
BACTERIA; DIMENSIONLESS NUMBERS; FOOD; MAGNOLIOPHYTA; MAGNOLIOPSIDA; MICROORGANISMS; PLANTS; VEGETABLES

Optional Information

Copyright
Copyright (c) 2021 Elsevier B.V. All rights reserved.