Published July 2009 | Version v1
Journal article

Granularity control in preparation process of nanosized Fe particles by flow-levitation method

  • 1. Research Center of Laser Fusion, China Academy of Engineering PHysics, Mianyang (China)
  • 2. Lab for Matter Characteristic Research at Extreme Condition, Southwest Univ. of Science and Technology, Mianyang (China)

Description

Nanosized Fe particles were prepared by flow-levitation method (FLM), and synthesis condition's effect on Fe nanopowder were investigated based on transmission electron micro-scope(TEM). The results show that FLM can be used to prepare nanosized Fe particles with different diameters, and the particle size of nanosized Fe gradually decreases by reduce the temperature of metal fused drop or increase gases speed. Moreover, increasing the inert gases pressure will decrease the average particle size at 1 500 degree C. However, the change rules of gas pressure's influence on average diameters of Fe particles will be inexistent at 1 600 degree C. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
43
Journal Issue
7
Journal Page Range
p. 636-639
ISSN
1000-6931

Optional Information

Notes
4 figs., 8 refs.