Published July 2009
| Version v1
Journal article
Granularity control in preparation process of nanosized Fe particles by flow-levitation method
Creators
- 1. Research Center of Laser Fusion, China Academy of Engineering PHysics, Mianyang (China)
- 2. Lab for Matter Characteristic Research at Extreme Condition, Southwest Univ. of Science and Technology, Mianyang (China)
Description
Nanosized Fe particles were prepared by flow-levitation method (FLM), and synthesis condition's effect on Fe nanopowder were investigated based on transmission electron micro-scope(TEM). The results show that FLM can be used to prepare nanosized Fe particles with different diameters, and the particle size of nanosized Fe gradually decreases by reduce the temperature of metal fused drop or increase gases speed. Moreover, increasing the inert gases pressure will decrease the average particle size at 1 500 degree C. However, the change rules of gas pressure's influence on average diameters of Fe particles will be inexistent at 1 600 degree C. (authors)
Additional details
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 43
- Journal Issue
- 7
- Journal Page Range
- p. 636-639
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 42073303
- Subject category
- S36: MATERIALS SCIENCE; S77: NANOSCIENCE AND NANOTECHNOLOGY;
- Descriptors DEI
- AUGMENTATION; CONTROL; ELECTRONS; GASES; ION BEAM TARGETS; IRON IONS; LEVITATION; METALS; PARTICLE SIZE; PARTICLES; POWDERS; SYNTHESIS; TEMPERATURE RANGE 1000-4000 K; TRANSMISSION ELECTRON MICROSCOPY
- Descriptors DEC
- CHARGED PARTICLES; ELECTRON MICROSCOPY; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; FLUIDS; IONS; LEPTONS; MICROSCOPY; SIZE; TARGETS; TEMPERATURE RANGE
Optional Information
- Notes
- 4 figs., 8 refs.