Published February 1988 | Version v1
Journal article

A new type personnel neutron dosimeter with thin SI detectors

  • 1. Institute for Atomic Energy, Rikkyo Univ., Nagasaka, Yokosuka, 240-01 (Japan)

Description

In this work, a newly developed Si detector system which is capable of distinguishing recoil protons from a hydrogen rich radiator depending on charged particles generated by /sup 6/Li(n, alpha)T nuclear reaction, is investigated, taking essential requirements for personnel dosimeters into account. This dosimeter is a rem counter based on a new principle. It possesses two different target materials and distinguishes low energy neutrons from fast neutrons. The detection efficiency as a function of neutron energy, is in accordance with the ''rem response''. This method makes it possible to make compact personnel neutron dosimeter with sufficient detection efficiency. This paper describes basic characteristics of the new neutron dosimeter and the evaluated results

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
35
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
575-578
ISSN
0018-9499
CODEN
IETNA

Conference

Title
34. nuclear science symposium and 19. nuclear power systems symposium.
Dates
21-23 Oct 1987.
Place
San Francisco, CA (USA).

Optional Information

Secondary number(s)
CONF-871006--.