Published April 15, 1990 | Version v1
Journal article

Investigation of an electromagnetic calorimeter based on liquid krypton

  • 1. AN SSSR, Novosibirsk. Inst. Yadernoj Fiziki
  • 2. Bologna Univ. (Italy)
  • 3. Istituto Nazionale di Fisica Nucleare, Bologna (Italy)
  • 4. Milan Univ. (Italy). Dipt. di Fisica
  • 5. Istituto Nazionale di Fisica Nucleare, Milan (Italy)
  • 6. Pavia Univ. (Italy). Dipt. di Elettronica

Description

Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E=130 MeV and 1.7% at E=1200 MeV. The measurements are compared to Monte Carlo simulations. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research, Section A
Journal Volume
289
Journal Issue
3
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
468-474
ISSN
0168-9002
CODEN
NIMAE

Conference

Title
4. Pisa meeting on advanced detectors.
Dates
22-26 May 1989.
Place