Treatment optimization through effectiveness monitoring
Creators
- 1. Structural Integrity Associates, Inc., San Jose, CA (United States)
- 2. Structural Integrity Associates, Inc., Parsippany, NJ (United States)
Description
Essentially all industries include treatments with corrosion inhibitors, deposit control agents, and biocides as a part of their control of general corrosion, localized corrosion, fouling, and microbiologically influenced corrosion (MIC) in cooling waters and process waters. Most such treatments rely exclusively on monitoring the concentrations of the control chemicals rather than monitoring the effectiveness of those treatments. Inhibitors and biocides are expensive, can produce undesirable side effects as they interact with other chemicals, and will always be subject to effluent controls. Over-dosing of treatment chemicals, especially oxidizing biocides, will have undesirable side effects, including increased corrosion of piping, heat exchangers, and process equipment. This presentation provides results of biofilm monitoring at Exelon's Peach Bottom Atomic Station, including biocide optimization efforts. (author)
Availability note (English)
Available as a slide presentation also.Additional details
Publishing Information
- Publisher
- Canadian Nuclear Society
- Imprint Place
- Toronto, Ontario (Canada)
- ISBN
- 978-1-926773-26-1
- Imprint Title
- Delivering clean energy through CANDU life extension. 11th International conference on CANDU maintenance and nuclear components
- Imprint Pagination
- 181 Megabytes
- Journal Page Range
- [13 p.]
Conference
- Title
- 11. international conference on CANDU maintenance and nuclear components
- Dates
- 1-4 Oct 2017
- Place
- Toronto, Ontario (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 50008920
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BIOLOGICAL FOULING; CHEMICAL EFFLUENTS; COOLANTS; CORROSION INHIBITORS; FOULING; HEAT EXCHANGERS; INDUSTRY; PIPES; WATER
- Descriptors DEC
- CHEMICAL WASTES; FOULING; HYDROGEN COMPOUNDS; NONRADIOACTIVE WASTES; OXYGEN COMPOUNDS; TUBES; WASTES
Optional Information
- Notes
- 14 refs., 6 figs.