Published 2017 | Version v1
Miscellaneous

Treatment optimization through effectiveness monitoring

  • 1. Structural Integrity Associates, Inc., San Jose, CA (United States)
  • 2. Structural Integrity Associates, Inc., Parsippany, NJ (United States)

Description

Essentially all industries include treatments with corrosion inhibitors, deposit control agents, and biocides as a part of their control of general corrosion, localized corrosion, fouling, and microbiologically influenced corrosion (MIC) in cooling waters and process waters. Most such treatments rely exclusively on monitoring the concentrations of the control chemicals rather than monitoring the effectiveness of those treatments. Inhibitors and biocides are expensive, can produce undesirable side effects as they interact with other chemicals, and will always be subject to effluent controls. Over-dosing of treatment chemicals, especially oxidizing biocides, will have undesirable side effects, including increased corrosion of piping, heat exchangers, and process equipment. This presentation provides results of biofilm monitoring at Exelon's Peach Bottom Atomic Station, including biocide optimization efforts. (author)

Availability note (English)

Available as a slide presentation also.
Part of:
Delivering clean energy through CANDU life extension. 11th International conference on CANDU maintenance and nuclear components

Additional details

Publishing Information

Publisher
Canadian Nuclear Society
Imprint Place
Toronto, Ontario (Canada)
ISBN
978-1-926773-26-1
Imprint Title
Delivering clean energy through CANDU life extension. 11th International conference on CANDU maintenance and nuclear components
Imprint Pagination
181 Megabytes
Journal Page Range
[13 p.]

Conference

Title
11. international conference on CANDU maintenance and nuclear components
Dates
1-4 Oct 2017
Place
Toronto, Ontario (Canada)

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
50008920
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BIOLOGICAL FOULING; CHEMICAL EFFLUENTS; COOLANTS; CORROSION INHIBITORS; FOULING; HEAT EXCHANGERS; INDUSTRY; PIPES; WATER
Descriptors DEC
CHEMICAL WASTES; FOULING; HYDROGEN COMPOUNDS; NONRADIOACTIVE WASTES; OXYGEN COMPOUNDS; TUBES; WASTES

Optional Information

Notes
14 refs., 6 figs.