Published December 1993 | Version v1
Report Restricted

Implementation of the FASTBUS data-acquisition system in the readout of the SAPHIR detector

Description

The magnetic detector SAPHIR is layed out to detect multiparticle final states with good acuracy, especially a good photon detection capability is designed. Therefore a large electromagnetic calorimeter was built, consisting of 98 modules covering a detection area of about 16 m2 in forward direction. For this calorimeter a brass-gas-sandwich detector was developed with signal wires perpendicular to the converter planes. For data acquisition of a major part of this calorimeter a modular FASTBUS system is used. In this report the FASTBUS system and its installation in the SAPHIR Online Program are described. (orig.)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (English)
Einbindung des FASTBUS-Datenerfassungssystems in die Auslese des SAPHIR-Detektors

Publishing Information

Imprint Pagination
47 p.
ISSN
0172-8741
Report number
BONN-IR--93-73