Published July 1, 1992
| Version v1
Journal article
Second harmonic magnicon amplifier experiment at 11.4 GHz
- 1. Beam Physics Branch, Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375-5000 (United States)
- 2. Icarus Research, Bethesda, Maryland 20814 (United States)
- 3. Senior Scientist for Fundamental Plasma Processes, Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375-5000 (United States)
Description
We present a report on a program to develop a high-power X-band magnicon amplifier for linear accelerator applications. The goal of the program is to generate 50 MW at 11.4 GHz with 50% efficiency, using a 200 A, 500 keV electron beam produced by a cold-cathode diode on the NRL Long-Pulse Accelerator Facility. The initial experiment, designed to study the gain from the first (driven) deflection cavity to a second (passive) deflection cavity, is under way
Additional details
Publishing Information
- Journal Title
- AIP Conference Proceedings
- Journal Volume
- 279
- Journal Issue
- 1
- Journal Page Range
- p. 67-73.
- ISSN
- 0094-243X
- CODEN
- APCPCS
Conference
- Title
- Advanced accelerator concepts workshop.
- Dates
- 14-20 Jun 1992.
- Place
- Port Jefferson, NY (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 25040206
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRON BEAMS; GHZ RANGE 01-100; KEV RANGE 100-1000; LINEAR ACCELERATORS; MICROWAVE AMPLIFIERS; PULSE TECHNIQUES
- Descriptors DEC
- ACCELERATORS; AMPLIFIERS; BEAMS; ELECTRONIC EQUIPMENT; ENERGY RANGE; EQUIPMENT; FREQUENCY RANGE; GHZ RANGE; KEV RANGE; LEPTON BEAMS; MICROWAVE EQUIPMENT; PARTICLE BEAMS
Optional Information
- Secondary number(s)
- CONF-9206193--.