Comparison of sound level meter calibration for frequency weighting parameter using coupler method
Creators
- 1. Center of Research and Human Resources Development, National Standardization Agency of Indonesia, Komplek Puspiptek Gedung 435, Tangerang Selatan, Banten (Indonesia)
Description
A large number of industrial needs to the sound level meter (SLM) calibration has encouraged the laboratory to develop a qualified calibration system. As one of the SLM calibration methods required by the standard, the coupler method is considered as the most convenient to be implemented, especially for the secondary laboratory. Therefore, the aim of this work is to compare the SLM calibration for the frequency weighting parameter by this method using the instrument standards that comprise of a multifunction acoustic calibrator and a working standard of pressure microphone (WS2-P Microphone). Moreover, the result of frequency weighting calibration using these standards, therefore, is compared to the reference value required by IEC 61672-1. From the result, the deviation values of these standards are obtained relative to the reference. At the low to middle frequencies, the deviation values are slight relatively, while at the higher frequency, it tends to bigger. In addition, these methods also support the development system of noise dosimeter and sound level meter calibration that still under research through the scheme of Incentive Research Program for the National Innovation System in 2020. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1742-6596/1896/1/012011Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Physics. Conference Series (Online)
- Journal Volume
- 1896
- Journal Issue
- 1
- Journal Page Range
- [8 p.]
- ISSN
- 1742-6596
Conference
- Title
- 1. Biennial International Conference on Acoustics and Vibration (Virtual Event)
- Acronym
- ANV 2020
- Dates
- 23-24 Nov 2020
- Place
- Surabaya (Indonesia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 53082443
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACOUSTICS; CALIBRATION; DOSEMETERS; METERS; NOISE; SOUND WAVES
- Descriptors DEC
- MEASURING INSTRUMENTS