Preparation Of Thermoluminescence Dosimeters For External Radiotherapy Beam Audit In Malaysia
- 1. Malaysian Nuclear Agency, Bangi, Kajang, Selangor (Malaysia)
Description
The external beam audit is a part of the Quality Assurance Programme (QAP) in radiotherapy that should be carried out to check the accuracy of dose delivered by the radiotherapy treatment units are within the tolerance limit of A ± 5 % as recommended by the International Commission of Radiation Units and Measurements (ICRU) Report No. 24. In this work, thermoluminescence dosimeters (TLD) in powder form were chosen to be used in the dose quality audit for the radiotherapy treatment units in Malaysia. As a preparation, the characterizations of a new batch of TLD-100 powders were studied. The studies include checks for the response of TLD-100 before and after pre-annealing process, reproducibility and linearity of TL signal. Results show that the response of TLD-100 powder after pre-annealing increases by 65 % compared with before pre-annealing process. These TLD-100 powders also provide reliable and consistent readings for the absorbed dose to water within the range of 150 cGy to 250 cGy with the maximum standard uncertainty of 0.554 μC. Finally, the calibration curves for 6 MV and 10 MV photon beams were established. These curves will be used in determining the absorbed dose to water (Dw) from user's irradiated TLDs. The expanded uncertainty (coverage factor k=2) of Dw determination was estimated to be 4.1 %. As a conclusion, these TLD-100 powders are ready to be used as a transfer detector for evaluating the accuracy of user's delivery dose in the radiotherapy beam audit program in Malaysia. (author)
Availability note (English)
Also available in Malaysian Nuclear Agency Document Delivery Center by email: mohdhafizal@nuclearmalaysia.gov.myFiles
46116548.pdf
Files
(1.5 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:e7f78f11996907c6d2e628786592e5ad
|
1.5 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 1 p.
- Report number
- INIS-MY--2015-102
Conference
- Title
- Research and Development Seminar 2014
- Acronym
- R&d Seminar 2014
- Dates
- 14-16 Oct 2014
- Place
- Bangi (Malaysia)
INIS
- Country of Publication
- Malaysia
- Country of Input or Organization
- Malaysia
- INIS RN
- 46116548
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ANNEALING; AUDITS; EXTERNAL IRRADIATION; QUALITY ASSURANCE; QUALITY CONTROL; RADIOTHERAPY; THERMOLUMINESCENCE; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- CONTROL; DOSEMETERS; EMISSION; HEAT TREATMENTS; IRRADIATION; LUMINESCENCE; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; PHOTON EMISSION; RADIOLOGY; THERAPY
Optional Information
- Notes
- Poster presentation