Published November 2018 | Version v1
Journal article

Impacts of a medium voltage direct current link on the performance of electrical distribution networks

  • 1. Institute of Energy, School of Engineering, Cardiff University, Cardiff CF24 3AA (United Kingdom)
  • 2. SP Energy Networks, Blantyre, Scotland G72 0HT (United Kingdom)

Description

Highlights: • Assessing impacts of an MVDC link on network performance with high DG penetrations. • Investigating the capability of an MVDC link in increasing the DG hosting capacity. • A real-time control method for MVDC link was proposed. • Control strategies considering multiple operational objectives were developed. With an increasing number of distributed generators (DGs) integrated into distribution networks, operational problems such as excessive power losses, voltage violations and thermal overloads have occurred. Medium Voltage Direct Current (MVDC) technology represents a candidate solution to address these problems as well as to unlock the capacity of existing electrical network assets. In this paper, the capability of using an MVDC link to improve the performance of a distribution network, i.e. reducing power losses and increasing the hosting capacity for DG connections was investigated. A grid transformer (GT)-based control method was developed, in which the real-time data of the active power flow at GTs was used to specify the set-points of an MVDC link. The control strategies considered multiple objectives, i.e. power loss reduction, feeder load balancing, voltage profile improvement, and trade-off options among them. The response curves of these control strategies were developed through offline studies, where a multi-objective Particle Swarm Optimization (MOPSO) method was used. Case studies on a real distribution network were conducted to analyze the impacts of the MVDC link. The performances of the network were evaluated and compared between the proposed control strategies, using real demand and generation profiles. Results revealed that, for an MV distribution network, it might be beneficial to switch between different control strategies with the variations in demand and generation conditions. Results also showed that, regardless of the control strategy used, the MVDC link can significantly increase the network hosting capacity (up to 15%) for DGs, and reduce about 50% of power losses compared to a conventional alternative current (AC) line for the test network.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apenergy.2018.08.077

Additional details

Identifiers

DOI
10.1016/j.apenergy.2018.08.077;
PII
S0306261918312224;

Publishing Information

Journal Title
Applied Energy
Journal Volume
230
Journal Page Range
p. 175-188
ISSN
0306-2619
CODEN
APENDX

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52103981
Subject category
S24: POWER TRANSMISSION AND DISTRIBUTION;
Descriptors DEI
CONTROL; DIRECT CURRENT; ELECTRIC POTENTIAL; OPTIMIZATION; PERFORMANCE; POWER DISTRIBUTION SYSTEMS; POWER LOSSES; POWER SYSTEMS; TRANSFORMERS
Descriptors DEC
CURRENTS; ELECTRIC CURRENTS; ELECTRICAL EQUIPMENT; ENERGY LOSSES; ENERGY SYSTEMS; EQUIPMENT; LOSSES

Optional Information

Copyright
Copyright (c) 2018 The Authors. Published by Elsevier Ltd.