Transcatheter closure of anastomotic leakage after surgical procedures for noninfected ascending aortic pathology
- 1. Interventional Department, Beijing Anzhen Hospital, Capital Medical University, Beijing (China)
- 2. Department of Radiology, National Cardiovascular Center, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing (China)
Description
Objective: To evaluate the safety and efficiency of transcatheter anastomotic leakage closure after surgical procedures for non-infected ascending aortic pathology with different occlusion devices. Methods: From Dec. 2013 to Sep. 2015, six cases received interventional therapy for anastomotic-leakage after surgical procedures for non-infected ascending aortic pathology using occluders. Four cases were with proximal graft-vessel anastomotic leakage, including two pseudoaneurysms at the site of aortic roots and two ascending aorta to right atrium shunts. The other two cases were with artificial grafts to intraoperative stent anastomotic leakage leading to endoleak type Ib. The anastomotic leakage was totally occluded by single ADO n respectively in four cases. Two detachable coils were implanted in one case with artificial graft to intraoperative stent anastomotic leakage, but mild residual shunt to false lumen was detected by DSA and follow-up CTA. The second interventional procedure was carried out one month later, and one ADO n was used to close the residual leakage totally. One PDA occluder was implanted along arteriovenous guide-wire track via aortic root to right atrium fistula in one case. Results: All the anastomotic leakages of the six cases were totally excluded by different occlude devices percutaneously. The technical success rate was 100%. Follow-up time was from 1 month to 4 years. The patients' clinical condition improved obviously. Follow-up CTA showed no recurrence of anastomotic leakage. Complete thrombosis and marked shrinkage of the pseudoaneurysm were achieved in two cases, and the partial thrombosis and shrinkage of the false lumen were achieved in 2 cases. Conclusion: Trans-catheter closure is an alternative treatment for ascending aortic surgical anastomotic leakage, which may achieve satisfactory short- and mid-term results. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Chinese Journal of Radiology
- Journal Volume
- 50
- Journal Issue
- 10
- Journal Page Range
- p. 774-778
- ISSN
- 1005-1201
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 52076371
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AORTA; ATRIA; BYPASSES; GRAFTS; LEAKS; PATHOLOGY; PATIENTS; RADIOLOGY; SAFETY; SHRINKAGE; SURGERY; THERAPY; THROMBOSIS
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; TRANSPLANTS; VASCULAR DISEASES
Optional Information
- Notes
- 12 figs., 1 tab., 10 refs.; http://dx.doi.org/10.3760/cma.j.issn.1005-1201.2016.10.009