Published September 2003 | Version v1
Journal article

Real-time environmental radiation monitoring system with automatic restoration of backup data in site detector via communication using radio frequency

  • 1. KAERI, Daejeon (Korea, Republic of)
  • 2. Samchang Company, Anyang (Korea, Republic of)

Description

An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using ratio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipment and also display together the current data as well as the transmitted backup data after checking time flag

Additional details

Publishing Information

Journal Title
Journal of the Korean Association for Radiation Protection
Journal Volume
28
Journal Issue
3
Series
4 refs, 6 figs, 1 tab
Journal Page Range
p. 255-261
ISSN
0253-4231

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
39068300
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
COMMUNICATIONS; ENVIRONMENTAL EFFECTS; KAERI; RADIATION MONITORING; SYNCHRONIZATION; TRANSMISSION
Descriptors DEC
KOREAN ORGANIZATIONS; MONITORING; NATIONAL ORGANIZATIONS