Published July 2008 | Version v1
Journal article

Coplanar capacitance sensors for detecting water intrusion in composite structures

  • 1. Department of Civil Engineering, McMaster University, Hamilton, Ontario L8S 4L7 (Canada)
  • 2. Component Life Technology, Atomic Energy of Canada Ltd, Chalk River, Ontario K0J 1P0 (Canada)

Description

Composite materials are becoming more affordable and widely used for retrofitting, rehabilitating and repairing reinforced concrete structures designed and constructed under older specifications. However, the mechanical properties and long-term durability of composite materials may degrade severely in the presence of water intrusion. This study presents a new non-destructive evaluation (NDE) technique for detecting the water intrusion in composite structures by evaluating the dielectric properties of different composite system constituent materials. The variation in the dielectric signatures was employed to design a coplanar capacitance sensor with high sensitivity to detect such defects. An analytical model was used to study the effect of the sensor geometry on the output signal and to optimize sensor design. A finite element model was developed to validate analytical results and to evaluate other sensor design-related parameters. Experimental testing of a concrete specimen wrapped with composite laminate and containing a series of pre-induced water intrusion defects was conducted in order to validate the concept of the new technique. Experimental data showed excellent agreement with the finite element model predictions and confirmed sensor performance

Availability note (English)

Available from http://dx.doi.org/10.1088/0957-0233/19/7/075702

Additional details

Identifiers

DOI
10.1088/0957-0233/19/7/075702;
PII
S0957-0233(08)76009-0;

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
19
Journal Issue
7
Journal Page Range
[7 p.]
ISSN
0957-0233
CODEN
MSTCEP