Published September 1993 | Version v1
Report Open

An air flow simulating test in the coolant channel of the core bottom of the 10 MW HTR module

  • 1. Qinghua Univ., Beijing, BJ (China). Inst. of Nuclear Energy Technology

Description

In order to investigate the efficiency of the thermal mixing of the coolant helium in the coolant channel of the core bottom and the hot gas duct, an air flow test has been performed on a scale of 1 to 1.5 analog simulating test model. The test facility and the test are described. The results of the simulating test indicate that the coolant channel designed in the core bottom reflector and the hot gas duct of the HTR-test Module possesses very good function of the coolant thermal mixing and can yield a non-dimensional temperature mixing degree of more than 98% and an uniformity of thermal distribution of over 99% at the exit of the hot gas duct

Availability note (English)

MF available from INIS under the Report Number.

Files

25050006.pdf

Files (496.0 kB)

Name Size Download all
md5:7780fc4948de68adbede6a100fb2733c
496.0 kB Preview Download

Additional details

Publishing Information

ISBN
7-5022-0975-1
Imprint Pagination
13 p.
Report number
CNIC--00790

Optional Information

Secondary number(s)
TSHUNE--0070.