COGAP: a nuclear power plant containment hydrogen control system evaluation code
Description
The accounting of containment gas concentration following a loss-of-coolant accident is important in the safety evaluation of hydrogen combustible-gas control systems for nuclear power plants. The COGAP code provides such accounting including the effects of (1) the reaction of zirconium and water; (2) radiolysis of core and sump water; (3) corrosion of zinc, aluminum and copper; (4) recirculation between compartments; (5) hydrogen recombiners; (6) purging; (7) nitrogen addition; and (8) atmospheric steam. Controls are available to determine when options are initiated; for example, the hydrogen recombiner can be started when the hydrogen concentration reaches a user-specified value
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 - GPO $3.75 as DE83006406.
Files
Additional details
Additional titles
- Augmented title (English)
- PWR;BWR
Publishing Information
- Imprint Pagination
- 28 p.
- Report number
- NUREG/CR--2847
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14761439
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BWR TYPE REACTORS; C CODES; CHEMICAL REACTIONS; CONTAINMENT BUILDINGS; CONTROLLED ATMOSPHERES; HYDROGEN; LOSS OF COOLANT; MATHEMATICAL MODELS; PWR TYPE REACTORS; REACTOR SAFETY
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; CONTAINMENT; ELEMENTS; NONMETALS; REACTOR ACCIDENTS; REACTORS; SAFETY; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- LA--9459-MS.