Published January 1983 | Version v1
Report Restricted

COGAP: a nuclear power plant containment hydrogen control system evaluation code

Description

The accounting of containment gas concentration following a loss-of-coolant accident is important in the safety evaluation of hydrogen combustible-gas control systems for nuclear power plants. The COGAP code provides such accounting including the effects of (1) the reaction of zirconium and water; (2) radiolysis of core and sump water; (3) corrosion of zinc, aluminum and copper; (4) recirculation between compartments; (5) hydrogen recombiners; (6) purging; (7) nitrogen addition; and (8) atmospheric steam. Controls are available to determine when options are initiated; for example, the hydrogen recombiner can be started when the hydrogen concentration reaches a user-specified value

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 - GPO $3.75 as DE83006406.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR;BWR

Publishing Information

Imprint Pagination
28 p.
Report number
NUREG/CR--2847

Optional Information

Secondary number(s)
LA--9459-MS.