A micro fluidic system to study the cytotoxic effect of drugs: the combined effect of celecoxib and 5-fluorouracil on normal and cancer cells

  • 1. Department of Microbioanalytics, Institute of Biotechnology, Warsaw University of Technology, 00-664, Warsaw (Poland)
  • 2. Department of Pharmacology, National Medicines Institute, 00-725, Warsaw (Poland)

Description

We have investigated the response of normal and cancer cells to exposure a combination of celecoxib (Celbx) and 5-fluorouracil (5-FU) using a lab-on-a-chip micro fluidic device. Specifically, we have tested the cytotoxic effect of Celbx on normal mouse embryo cells (Balb/c 3T3) and human lung carcinoma cells (A549). The single drugs or their combinations were adjusted to five different concentrations using a concentration gradient generator (CGG) in a single step. The results suggest that Celbx can enhanced the anticancer activity of 5-FU by stronger inhibition of cancer cell growth. We also show that the A549 cancer cells are more sensitive to Celbx than the Balb/c 3T3 normal cells. The results obtained with the micro fluidic system were compared to those obtained with a macro scale in vitro cell culture method. In our opinion, the micro fluidic system represents a unique approach for an evaluation of cellular response to multidrug exposure that also is more simple than respective micro well plate assays. (author)